SAE-AMS-2644 is a standard developed by the Society of Automotive Engineers (SAE) that defines the requirements for non-destructive testing (NDT) penetrant materials used in liquid penetrant inspection (LPI) processes. This inspection method is widely used in various industries including aerospace, automotive, and manufacturing. It is used to detect surface discontinuities such as cracks, porosity, and inclusions in non-porous materials like metals, ceramics, and plastics. This specification is part of the Aerospace Material Specifications (AMS) series.

AMS 2644 Products

Silmid P/N: 
P014802
MFR PN: 
50811071 ...
50811071 | 50822819
From £19.27 excl VAT
In Stock
Silmid P/N: 
P0200200
MFR PN: 
50836574
£446.85 excl VAT
No Stock – Lead time 33 business days from date of order confirmation
Silmid P/N: 
P1500047
MFR PN: 
50836596
£633.84 excl VAT
No Stock – Lead time 12 business days from date of order confirmation
Silmid P/N: 
VAR0001519
MFR PN: 
2050002405 ...
2050002405 | 50595880 | 50836568
From £25.80 excl VAT
In Stock
Silmid P/N: 
P0200198
MFR PN: 
50836507
£1019.64 excl VAT
In Stock - 1 Available
Silmid P/N: 
P0220597
MFR PN: 
50713175
£30.71 excl VAT
No Stock – Lead time 26 business days from date of order confirmation
Silmid P/N: 
P0200199
MFR PN: 
50590998
£1357.67 excl VAT
No Stock – Lead time 33 business days from date of order confirmation
Silmid P/N: 
VAR0001521
MFR PN: 
2050002408 ...
2050002408 | 50641514
From £762.06 excl VAT
No Stock – Lead time 26 business days from date of order confirmation
Silmid P/N: 
VAR0001522
MFR PN: 
50591311 ...
50591311 | 50591313
From £616.03 excl VAT
No Stock – Lead time 19 business days from date of order confirmation
Silmid P/N: 
VAR0001523
MFR PN: 
50825006 ...
50825006 | 50836554
From £308.43 excl VAT
In Stock
Silmid P/N: 
VAR0001524
MFR PN: 
50739121 ...
50739121 | 50836536
From £43.79 excl VAT
No Stock – Lead time 19 business days from date of order confirmation
Silmid P/N: 
AR988125LT
MFR PN: 
50836547
£716.50 excl VAT
No Stock – Lead time 19 business days from date of order confirmation
Silmid P/N: 
VAR0001525
MFR PN: 
50595825 ...
50595825 | 50836592
From £14.31 excl VAT
In Stock
Silmid P/N: 
A9D1B00400
MFR PN: 
50595791
£13.54 excl VAT
In Stock - 229 Available
Silmid P/N: 
AR9D400500
MFR PN: 
50833209
£33.78 excl VAT
In Stock - 12 Available
Silmid P/N: 
VAR0000552
MFR PN: 
50595814 ...
50595814 | 50836493
From £16.17 excl VAT
In Stock
Silmid P/N: 
P1400485
MFR PN: 
50595817
£16.42 excl VAT
In Stock - 49 Available
Silmid P/N: 
P1500165
MFR PN: 
50635881
£114.55 excl VAT
No Stock – Lead time 26 business days from date of order confirmation
Silmid P/N: 
P1400223
MFR PN: 
50595819
£15.12 excl VAT
In Stock - 1 Available
Silmid P/N: 
P0210631
MFR PN: 
-
£243.65 excl VAT
No Stock – Lead time 26 business days from date of order confirmation

Key Features of SAE-AMS-2644

AMS-2644 covers the composition and performance characteristics of penetrant materials used in liquid penetrant inspection. These materials include:

  • Penetrants: Fluids applied to the surface of the test part to seep into surface flaws.
  • Emulsifiers: Used to make penetrants water-washable in post-application cleaning.
  • Developers: A substance that draws the penetrant out of the discontinuity and makes it visible.
  • Types and Methods

    The specification classifies penetrants into different types based on their removal method

    Type I: Fluorescent penetrants, which require ultraviolet (UV) light to detect defects.
    Type II: Visible penetrants, which are detected in normal light and do not require UV light. These penetrants can be further categorised based on their method of removal:

    Method A: Water-washable penetrants.
    Method B: Post-emulsifiable, lipophilic (oil-based) penetrants.
    Method C: Solvent-removable penetrants.
    Method D: Post-emulsifiable, hydrophilic (water-based) penetrants.

    Sensitivity levels

    In this context refer to the ability of a penetrant to detect surface discontinuities, such as cracks, porosity, or other defects. Higher sensitivity levels indicate that the penetrant can detect smaller and finer indications.

    AMS 2644 defines five sensitivity levels for fluorescent liquid penetrants:

    1. Level ½: Very low sensitivity.
    2. Level 1: Low sensitivity.
    3. Level 2: Medium sensitivity.
    4. Level 3: High sensitivity.
    5. Level 4: Ultrahigh sensitivity.


    The choice of sensitivity level depends on the specific application and the type of defects being sought. For example, a high-sensitivity penetrant might be necessary for detecting very fine cracks in critical components, while a lower sensitivity level might suffice for general inspections.

    Key factors to consider when selecting a sensitivity level:

    • Nature of the defect: The size, shape, and orientation of the defect will influence the required sensitivity.
    • Material properties: The surface finish, porosity, and other material characteristics can affect the penetrant's ability to reveal defects.
    • Inspection requirements: The specific standards or regulations governing the inspection will dictate the minimum sensitivity level.